HOT PRODUCTS
        SOLUTIONS
        PRODUCTS
        • 标题: SCA126T
        • 型号: Dual-axis digital output inclinometer
        • 概述:
        • 1: ●Dual-Axis Inclinometer
        • 2: ●Measuring Range :±1~±90° optional
        • 3: ●Wide voltage input: 9~36V
        • 4: ●Wide temperature working: -40~+85℃
        • 5: ●Resolution: 0.01°
        • 6: ●Small size :90×40×26mm(customized)
        • 7: ●Output mode RS232/RS485/RS422/PWM/CAN (optional)

         

         

        General Description


         SCA126T is a serial output dual-axis inclinometer launched by RION company to the field of industrial control, built-in high-precision A / D differential converter, through 5 filtering algorithm, which can measure the angle of sensor output relative to the horizontal tilt and pitch tilt. The output interface RS485, RS232, RS422, TTL, CAN、MODBUS are optional.
         Because of Built in ADI company’s high precision digital temperature sensor that can correct the sensor temperature drift in accordance with the changes of the built-in temperature sensor, to ensure high repeatability of the product in the low-temperature and high-temperature environment. The output frequency response standards up to 18Hz, for higher response frequency Division we can customize according to the user requests. The products are truly industrial-grade products, reliable performance, scalability, and a variety of output options. Suitable for a variety of harsh industrial control environment.

         

        Technical Data

        Parameters 

        Conditions 

        SCA126T-10 

        SCA126T-30 

        SCA126T-60 

        SCA126T-90 

         
        Measuring range   ±10 ±30 ±60 ±90 °
        Measuring axis   X,Y X,Y X,Y X,Y  
        Resolution   0.01 0.02 0.03 0.04 °
        Absolute accuracy   0.02 0.05 0.08 0.1 °
        Long termstability   0.05 0.05 0.05 0.05  
        Zerotemp. coefficient -40~85° ±0.006 ±0.006 ±0.006 ±0.006 °/℃
        Sensitivity temp. coefficient -40~85° ≤100 ≤100 ≤100 ≤100 ppm/℃
        Power on time   0.5 0.5 0.5 0.5 S
        Response time   0.05 0.05 0.05 0.05 s
        Output rate 5Hz、15Hz、35Hz、50Hz can be setting
        Output signal RS232/RS485/RS422/TTL/PWM/CAN/MODBUS
        EMC According to EN61000 and GBT17626
        MTBF ≥50000hours/times
        Insulation Resistance ≥100M
        Shockproof 100g@11ms、3Times/Axis(half sinusoid))
        Anti-vibration 10grms、10~1000Hz
        Protection glass IP67
        Cables Standard 1M length、wearproof、grease proofing、wide temperature、Shielded cables 4*0.4mm2
        Weight 120g(without cable)

         

        Dimension

         

        Electrical Characteristics

         

        Parameters

        Conditions

        Min

        Standard

        Max

        Units

        Power supply Standard 9 12、24 36 V
          customized   5   V
        Working current  non-loaded   30   mA
        Working temperature   -40   85
        Store temperature   -55   125

         

        Electrical Connection

         

        Line color function BLACK WHITE GREEN RED
          GNDPower Negative

        RS232(RXD)

        RS485(D+)

        RS232(TXD)

        RS485(D-)

        DC9~36V

        Ordering information 

         

         

        Specification Download


         

        SCA126T SPECIFICATION DOWNLOAD